Let the IT Equipment Run Seamlessly With Loadbank Testing

01/11/2018

We all know the importance of UPS or Uninterrupted Power Supply to run IT equipment. With the presence of UPS, you can keep running systems (Server and other peripheral items) during the short-term power outage. It provides the temporary power backup for few minutes. The system uses batteries for energy storage and addresses the power failures inside an organisation.

It is a fact to remember that UPS system is not meant to support the heavy load equipment like fire pump or heating/cooling systems. To use the UPS system according to the perspective, you need to consider its energy source. Batteries in the UPS system are responsible for storing the energy.

Why is it necessary to conduct loadbank testing for UPS systems?

UPS systems will stand between the backup power generators and IT equipment. As we all know, the continuous power supply is necessary for data centres to maintain the continuity in the business. Hence, it is necessary to upkeep the power supply that needs loadbank to test your UPS.

With loadbank testing, you can validate the operational performance of the UPS and its batteries. Being loadbank tested, it will allow your UPS system to take the load without risking other equipment while working. For example, think about the simulator flight training, where you can operate a plane without the risk of crashing it. Similarly, loadbank let you run the operational units, without even experiencing the power outage.

How loadbank testing work for UPS?

While conducting data centre commissioning process (Reducing the possibility of unplanned down time), you can perform the UPS loadbank testing. Before testing, you have to equalize the voltage to across the different battery blocks and make sure that the batteries are fully charged. In order to receive the accurate results, loadbank suppliers recommend testing no before it completes one week after commissioning the UPS system.

Apart from the commissioning phase, UPS loadbank testing is also performed during the preventive maintenance. With a portable loadbank rental, professionals evaluate the condition of the batteries installed in the UPS system along with the battery strings. In case any individual cell fails to retain the charge or if the batteries are running at the end of their working life, the load test will reveal the issue. As a result, you can replace the batteries before the entire thing becomes complex.

What are the available types of testing for UPS batteries?

Under the guidance of loadbank suppliers, you can rent the appropriate one to test your UPS. Either AC or DC resistive loadbanks perform the UPS load testing. Even though you can use reactive load banks, people generally spare using reactive loadbank, as they are heavier in size. Whereas a DC loadbank can test UPS batteries, an AC resistive loadbank can test the entire UPS system.

As the loadbank produce heat, ask the supplier for heat dissipation during the testing. Moreover, the fans of the loadbank system create noise while it provides cooling to its internal system. Hence, you can ask the provider to conduct testing away from staff and workplace.